NKG, back to back (shaft seal, HJ92N-HJ92N) – Grundfos Service Video



NKG, back to back (shaft seal, HJ92N-HJ92N)

Table of contents:

Dismantling:
00:00 Removing the pump housing
02:41 Removing the impeller
03:52 Removing the primary shaft seal
05:19 Removing the secondary shaft seal

Assembly:
06:10 Fitting the secondary shaft seal
08:31 Fitting the primary shaft seal
10:56 Fitting the impeller
12:04 Fitting pump housing

15:28 Wear ring replacement

Recorded: January 2010

For more information please visit:

https://www.grundfos.com/service-support.html

Send your message to us:

INQUIRY NOW
  • * CAPTCHA: Please select the Heart


Post time: Jun-28-2017